We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

ObjectivesLittle data exist regarding the potential of external stents to mitigate long-term disease progression in saphenous vein grafts. We investigated the effect of external stents on the progression of saphenous vein graft disease.MethodsA total of 184 patients undergoing isolated coronary artery bypass grafting, using an internal thoracic artery graft and at least 2 additional saphenous vein grafts, were enrolled in 14 European centers. One saphenous vein graft was randomized to an external stent, and 1 nonstented saphenous vein graft served as the control. The primary end point was the saphenous vein graft Fitzgibbon patency scale assessed by angiography, and the secondary end point was saphenous vein graft intimal hyperplasia assessed by intravascular ultrasound in a prespecified subgroup at 2 years.ResultsAngiography was completed in 128 patients and intravascular ultrasound in the entire prespecified cohort (n = 51) at 2 years. Overall patency rates were similar between stented and nonstented saphenous vein grafts (78.3% vs 82.2%, P = .43). However, the Fitzgibbon patency scale was significantly improved in stented versus nonstented saphenous vein grafts, with Fitzgibbon patency scale I, II, and III rates of 66.7% versus 54.9%, 27.8% versus 34.3%, and 5.5% versus 10.8%, respectively (odds ratio, 2.02; P = .03). Fitzgibbon patency scale was inversely related to saphenous vein graft minimal lumen diameter, with Fitzgibbon patency scale I, II, and III saphenous vein grafts having an average minimal lumen diameter of 2.62 mm, 1.98 mm, and 1.32 mm, respectively (P ConclusionsTwo years after coronary artery bypass grafting, external stenting improves Fitzgibbon patency scales of saphenous vein grafts and significantly reduces intimal hyperplasia area and thickness. Whether this will eventually lead to improved long-term patency is still unknown.

Original publication

DOI

10.1016/j.jtcvs.2021.03.120

Type

Journal article

Journal

The Journal of thoracic and cardiovascular surgery

Publication Date

21/04/2021

Addresses

Nuffield Department of Surgical Sciences, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom.

Keywords

InVESTigators